F1
SMEG Indoor Evaporator Coil Temperature Sensor Fault

F1 error; unit may run fan only and not cool/heat properly

Advertisements

Possible Causes

Failed evaporator NTC sensor, Sensor dislodged from coil, Broken sensor harness, Corroded connector at indoor PCB

How to Fix / Troubleshooting

Safety first: Disconnect power before removing covers.

  • Locate evaporator sensor: It is usually clipped onto the evaporator coil tubing near the center or side of the coil.
  • Check mounting: Ensure the sensor is firmly attached to the coil surface for accurate readings.
  • Inspect connector: Reseat the sensor connector on the indoor PCB and check for corrosion.
  • Replace sensor: If F1 remains, install a new SMEG evaporator NTC sensor with the correct rating.

After replacement, clear the error by power cycling the unit.