F3
SMEG
Outdoor Coil Temperature Sensor Fault
F3 error; unit may stop during heating mode
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed outdoor coil NTC sensor, Sensor detached from coil, Damaged sensor wiring, Corroded connector at outdoor PCB
How to Fix / Troubleshooting
Safety first: Isolate power at the breaker.
- Locate coil sensor: It is clipped to the outdoor heat exchanger tubing.
- Check attachment: Ensure the sensor is firmly clipped and in good thermal contact with the coil.
- Inspect wiring: Look for insulation damage or pulled wires.
- Replace sensor: If F3 remains after reseating, replace the outdoor coil NTC sensor with the correct SMEG part.
After replacement, restore power and test in heating mode.