F3
SMEG Outdoor Coil Temperature Sensor Fault

F3 error; unit may stop during heating mode

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor coil NTC sensor, Sensor detached from coil, Damaged sensor wiring, Corroded connector at outdoor PCB

How to Fix / Troubleshooting

Safety first: Isolate power at the breaker.

  • Locate coil sensor: It is clipped to the outdoor heat exchanger tubing.
  • Check attachment: Ensure the sensor is firmly clipped and in good thermal contact with the coil.
  • Inspect wiring: Look for insulation damage or pulled wires.
  • Replace sensor: If F3 remains after reseating, replace the outdoor coil NTC sensor with the correct SMEG part.

After replacement, restore power and test in heating mode.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Coil Temperature Sensor (NTC)