SMEG Outdoor Unit Not Responding / Control or Power Fault

Unit powers on but compressor and outdoor fan never start; only indoor fan runs

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No power supply to outdoor unit, Faulty interconnecting cable, Blown outdoor PCB fuse, Failed outdoor main PCB

How to Fix / Troubleshooting

Safety first: Isolate power before opening the outdoor unit.

  • Check outdoor isolator: Ensure the external disconnect switch near the outdoor unit is ON.
  • Verify voltage at outdoor terminals: A qualified person should measure mains voltage at the outdoor unit.
  • Inspect interconnecting cable: Confirm that the cable between indoor and outdoor units is intact and correctly wired.
  • Check outdoor PCB fuse: Replace a blown fuse only with the same rating; if it blows again, there is likely a short in the PCB or compressor circuit.

If the outdoor unit still does not start, the outdoor PCB or compressor may be faulty and requires professional diagnosis.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Main Control PCB
Check Price on Amazon