Possible Causes

Indoor fan motor hall sensor failure, Obstructed blower wheel, Faulty indoor PCB fan driver, Incorrect fan motor replacement previously installed

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the indoor fan assembly.

  • Step 1 – Clean blower wheel: Remove the front panel and filters. Inspect the blower wheel for heavy dust buildup and clean with a brush and vacuum.
  • Step 2 – Check wiring: Ensure the multi-pin connector from the fan motor to the PCB is secure.
  • Step 3 – Test fan speeds: Restore power and cycle through fan speeds. If the fan does not respond correctly or F6 appears, the motor or PCB is suspect.
  • Step 4 – Replace indoor fan motor: Install a new TCL-specified DC fan motor if the existing one has faulty feedback.
  • Step 5 – Replace PCB if needed: If a new motor does not resolve F6, replace the indoor main PCB.

Warning: Incorrect fan speed can cause coil freezing or overheating; do not ignore F6 errors.