F7
TCL Outdoor Fan Motor Fault / Feedback Error

Unit shows F7 and may not start compressor

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DC outdoor fan motor, Loose fan motor connector, Obstructed fan blades, Faulty outdoor PCB fan driver circuit

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before opening the outdoor unit.

  • Step 1 – Inspect fan blades: Remove any debris or objects blocking the fan. Ensure blades are not cracked or bent.
  • Step 2 – Spin test: With power off, spin the fan by hand. It should rotate freely. Stiffness indicates bearing failure.
  • Step 3 – Check connector: Verify the fan motor connector is firmly attached to the outdoor PCB.
  • Step 4 – Test operation: Restore power and run COOL mode. If the fan does not start and F7 appears, replace the outdoor fan motor.
  • Step 5 – PCB check: If a new motor does not fix the issue, the outdoor PCB may be defective and require replacement.

Warning: Never run the compressor without a functioning outdoor fan; this can cause rapid overheating and damage.