TCL
Outdoor Mechanical Noise / Fan or Compressor Issue
Loud humming or grinding noise from outdoor unit
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose outdoor fan blade on TCL condenser, Worn outdoor fan motor bearings, Compressor mounting rubbers deteriorated, Debris stuck in fan guard
How to Fix / Troubleshooting
Safety first: Turn OFF power at the breaker before working on the outdoor unit.
- Step 1 – Inspect fan area: Remove the top grille (if accessible) and clear any debris from the fan and guard.
- Step 2 – Check fan blade: Ensure the blade is tight on the motor shaft. Tighten the set screw if loose.
- Step 3 – Check vibration mounts: Inspect compressor and unit mounting rubbers. Replace if cracked or missing.
- Step 4 – Motor/compressor diagnosis: If noise is internal to the compressor or motor, replacement may be required by a technician.
Warning: Do not bend fan blades; imbalance can cause further noise and damage.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Outdoor Fan Blade
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements