Possible Causes

Loose outdoor fan blade on TCL condenser, Worn outdoor fan motor bearings, Compressor mounting rubbers deteriorated, Debris stuck in fan guard

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before working on the outdoor unit.

  • Step 1 – Inspect fan area: Remove the top grille (if accessible) and clear any debris from the fan and guard.
  • Step 2 – Check fan blade: Ensure the blade is tight on the motor shaft. Tighten the set screw if loose.
  • Step 3 – Check vibration mounts: Inspect compressor and unit mounting rubbers. Replace if cracked or missing.
  • Step 4 – Motor/compressor diagnosis: If noise is internal to the compressor or motor, replacement may be required by a technician.

Warning: Do not bend fan blades; imbalance can cause further noise and damage.