Possible Causes

Faulty indoor-outdoor communication cable on TCL split system, Defective outdoor main PCB, Failed compressor, Incorrect mode or temperature settings

How to Fix / Troubleshooting

Safety first: Turn OFF power before opening any covers.

  • Step 1 – Confirm settings: Ensure the unit is in COOL or HEAT mode (not FAN or DRY) and the set temperature is appropriate.
  • Step 2 – Listen for outdoor unit: When starting, listen outside for any click or hum. Total silence may indicate no power or PCB failure.
  • Step 3 – Check communication cable: Inspect the cable between indoor and outdoor units for damage and verify terminal connections.
  • Step 4 – Professional diagnosis: A technician should check for control voltage to the compressor and fan, and test the outdoor PCB and compressor.

Warning: Do not repeatedly cycle power hoping the compressor will start; this can stress electrical components.