F2
Tempstar
Evaporator Coil Temperature Sensor Fault
Tempstar ductless mini-split indoor unit displays F2 and cooling stops
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective evaporator thermistor, Sensor out of position on coil, Broken sensor wiring, Faulty indoor control board
How to Fix / Troubleshooting
Safety first: Turn OFF power to the indoor unit.
Steps:
- 1. Access coil area: Remove the front cover and filters to expose the evaporator coil.
- 2. Locate coil sensor: The thermistor is clipped to the coil tubing. Ensure it is firmly attached and making good contact.
- 3. Inspect wiring: Follow the sensor wires back to the control board. Look for cuts, pinches, or loose connectors.
- 4. Reseat connector: Unplug and replug the sensor connector on the board to ensure a good connection.
- 5. Test operation: Restore power and run the unit. If F2 returns, the sensor likely needs replacement by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Coil Thermistor
Check Price on Amazon