F2
Tempstar Evaporator Coil Temperature Sensor Fault

Tempstar ductless mini-split indoor unit displays F2 and cooling stops

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective evaporator thermistor, Sensor out of position on coil, Broken sensor wiring, Faulty indoor control board

How to Fix / Troubleshooting

Safety first: Turn OFF power to the indoor unit.

Steps:

  • 1. Access coil area: Remove the front cover and filters to expose the evaporator coil.
  • 2. Locate coil sensor: The thermistor is clipped to the coil tubing. Ensure it is firmly attached and making good contact.
  • 3. Inspect wiring: Follow the sensor wires back to the control board. Look for cuts, pinches, or loose connectors.
  • 4. Reseat connector: Unplug and replug the sensor connector on the board to ensure a good connection.
  • 5. Test operation: Restore power and run the unit. If F2 returns, the sensor likely needs replacement by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Coil Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements