F8
Tempstar Indoor Fan Speed Feedback Fault

Tempstar ductless mini-split indoor unit displays F8 and unit stops after short operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed indoor DC fan motor, Blocked blower wheel, Loose motor connector, Faulty indoor control board

How to Fix / Troubleshooting

Safety first: Turn OFF power to the indoor unit.

Steps:

  • 1. Remove front cover and filters: Access the blower wheel area.
  • 2. Check for obstructions: Remove any debris or buildup on the blower wheel.
  • 3. Inspect motor connector: Ensure the DC motor plug is firmly connected to the indoor control board.
  • 4. Spin blower by hand: It should rotate freely. If stiff, the motor bearings may be failing.
  • 5. Restore power and test: If F8 persists, the motor or board will need replacement by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor DC Fan Motor
Check Price on Amazon