Possible Causes

Oversized system, Blower speed set too high, Short cycling, Low refrigerant charge

How to Fix / Troubleshooting

Safety first: Turn OFF power before adjusting blower settings; many adjustments should be done by a technician.

Steps:

  • 1. Set fan to AUTO: Ensure thermostat fan mode is AUTO, not ON. Continuous fan can re-evaporate moisture.
  • 2. Check runtime: If the Tempstar system only runs for very short periods, it may be oversized or short cycling; see short cycling entry.
  • 3. Discuss blower speed: Ask your HVAC technician to verify that blower speed is set correctly for dehumidification per Tempstar specifications.
  • 4. Consider controls: A professional can add dehumidification controls or adjust CFM/ton if appropriate.