Tempstar Outdoor Unit Non-Operation

Tempstar air conditioner outdoor unit does not run but indoor blower does

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped outdoor disconnect, Failed contactor, Open high-pressure or low-pressure switch, Broken low-voltage control wire

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before opening panels.

Steps:

  • 1. Check outdoor disconnect: Ensure the pull-out or breaker at the Tempstar condenser is fully inserted and ON.
  • 2. Listen for contactor click: With thermostat calling for cooling, you should hear a click from the contactor. If not, the contactor may not be energizing.
  • 3. Inspect low-voltage wires: Look for broken or chewed thermostat wires at the outdoor unit.
  • 4. Visual check of contactor: If contacts are badly burned or pitted, replacement is needed.
  • 5. Call a technician: Testing safeties and replacing contactors should be done by a professional.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Contactor
Check Price on Amazon