E10
Toshiba Indoor Unit EEPROM / Configuration Error

Unit does not respond to remote; E10 may flash on some Toshiba models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted EEPROM data on indoor PCB, Incorrect PCB replacement (wrong model code), Loose configuration jumper or DIP switch, Failed indoor control PCB

How to Fix / Troubleshooting

Safety first: Turn off power before opening the indoor electrical compartment.

  • Step 1 – Power reset: Disconnect power for at least 10 minutes to allow the control to fully discharge. Restore power and test.
  • Step 2 – Check model configuration: On the indoor PCB, locate any DIP switches or jumpers used to set capacity or mode. Verify they match the unit’s rating label and Toshiba service manual.
  • Step 3 – Inspect PCB for damage: Look for burnt components, corrosion, or insect damage on the indoor PCB.
  • Step 4 – Reinitialize (if supported): Some Toshiba models allow an initialization procedure via remote (e.g., service mode). Follow the service manual to re-register the indoor unit.
  • Step 5 – Replace PCB: If E10 persists, the indoor PCB (with EEPROM) may need replacement with the exact Toshiba part number for your model.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Indoor Control PCB (with EEPROM)
Check Price on Amazon

We may earn a commission from links on this page.