E13
Toshiba
Four-Way Reversing Valve Fault / Position Error
Unit stops with E13; often occurs in heating mode on multi-split Toshiba systems.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck four-way valve, Faulty four-way valve coil, Incorrect wiring to valve coil, Faulty outdoor PCB output to valve
How to Fix / Troubleshooting
Safety first: Disconnect power and do not attempt to heat the valve with open flame. Refrigerant circuit must only be opened by licensed technicians.
- Step 1 – Listen for valve shift: Command the unit from cooling to heating and listen at the outdoor unit for a distinct click of the four-way valve coil energizing.
- Step 2 – Check coil wiring: With power off, inspect the two wires going to the four-way valve coil. Ensure they are firmly connected and not damaged.
- Step 3 – Coil resistance: Disconnect the coil and measure resistance. Compare to Toshiba specifications (typically tens of ohms). Replace if open or shorted.
- Step 4 – PCB output check: If the coil is good, a technician should verify the outdoor PCB is supplying the correct voltage to the coil in heating mode.
- Step 5 – Mechanical valve issue: If the coil energizes but the valve does not shift (no change in pipe temperatures), the valve may be stuck and require replacement by a professional.