E14
Toshiba Compressor Start Failure / Inverter Module Error

Unit shows E14; compressor does not start or stops quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed inverter IPM (Intelligent Power Module), Shorted compressor windings, Loose compressor terminal connections, DC bus over/under-voltage

How to Fix / Troubleshooting

Safety first: This fault involves high-voltage inverter electronics. Disconnect power and do not touch the inverter board capacitors until discharged. Only qualified personnel should perform detailed tests.

  • Step 1 – Visual inspection: Remove the outdoor cover and inspect the inverter PCB for burnt components, cracked solder joints, or bulging capacitors.
  • Step 2 – Check compressor terminals: With power off, remove the compressor terminal cover and ensure all spade connectors are tight and not burnt.
  • Step 3 – Insulation test (technician): A technician should perform a megohm test between compressor windings and ground to rule out a short.
  • Step 4 – Replace inverter PCB: If the compressor tests good but E14 persists, the inverter power module/PCB usually must be replaced with the correct Toshiba part.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter Power PCB
Check Price on Amazon