E25
Toshiba
Outdoor Ambient Temperature Sensor Fault
Unit displays E25; may be associated with abnormal outdoor ambient temperature readings.
Advertisements
Possible Causes
Failed outdoor ambient thermistor, Sensor dislodged from mounting, Damaged sensor cable, Faulty outdoor PCB sensor input
How to Fix / Troubleshooting
Safety first: Turn off power at the outdoor disconnect before working on the unit.
- Step 1 – Locate ambient sensor: Find the small sensor usually mounted near the outdoor air intake grille.
- Step 2 – Inspect mounting and wiring: Ensure the sensor is exposed to outdoor air (not touching hot pipes) and the cable is intact.
- Step 3 – Check connector: Verify the sensor plug is firmly connected to the outdoor PCB.
- Step 4 – Measure resistance: Disconnect and measure resistance, comparing to Toshiba’s chart for the current outdoor temperature. Replace if readings are abnormal.
- Step 5 – Replace sensor: Install a new ambient temperature sensor and secure it in the original location.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Outdoor Ambient Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements