F02
Toshiba High-Pressure Protection Activated

Unit shows F02; often associated with high-pressure protection on outdoor unit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked outdoor coil, Failed outdoor fan motor, Overcharged refrigerant, Non-condensable gases in system

How to Fix / Troubleshooting

Safety first: Turn off power and keep clear of hot components. Refrigerant work must be done by licensed technicians.

  • Step 1 – Clean outdoor coil: Remove debris and wash the coil with low-pressure water.
  • Step 2 – Check outdoor fan: Confirm the fan starts and runs at full speed. Replace the fan motor if it fails to run.
  • Step 3 – Ensure clearance: Provide adequate space around the outdoor unit for airflow.
  • Step 4 – Technician tasks: If F02 persists, a technician should check system pressures, refrigerant charge, and high-pressure switch operation.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

High-Pressure Switch / Outdoor Fan Motor
Check Price on Amazon