E7
Tosot
Mode Conflict / Reversed Valve or Indoor–Outdoor Mode Mismatch
Indoor unit displays E7, outdoor unit may not start
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect wiring between indoor and outdoor units, Faulty 4-way reversing valve coil, Outdoor PCB not responding to mode command, Indoor PCB logic fault
How to Fix / Troubleshooting
Safety first: Turn off power to the entire system before opening any covers.
- Confirm wiring: Verify that the interconnecting cable between indoor and outdoor units is wired exactly as per the Tosot installation manual. Correct any miswiring.
- Power reset: After correcting wiring, power down for 10 minutes, then restore power and test heating and cooling modes.
- Check reversing valve coil: On heat pump models, locate the 4-way valve coil on the outdoor unit. Ensure the coil is firmly attached and its connector is secure. If the coil is open-circuit (technician test), replace it.
- If E7 persists: Either the indoor or outdoor PCB may not be processing mode commands correctly. A technician should diagnose communication and replace the faulty board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
4-Way Reversing Valve Coil
Check Price on Amazon