F2
Tosot Indoor Evaporator Temperature Sensor Fault

Indoor unit displays F2, unit may shut down or run erratically

Advertisements

Possible Causes

Open or shorted evaporator coil sensor (T1), Loose or corroded sensor connector, Sensor dislodged from coil surface, Damaged sensor harness

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the front cover.

  • Access the coil: Remove the front panel and filters to expose the evaporator coil.
  • Locate sensor: Find the T1 sensor clipped to the coil tubing. Ensure it is firmly attached and not hanging loose.
  • Check wiring: Trace the sensor wires back to the PCB and reseat the connector.
  • Replace sensor: If F2 persists, replace the evaporator temperature sensor with the correct Tosot part.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Indoor Evaporator Temperature Sensor (T1)
Check Price on Amazon

We may earn a commission from links on this page.