F2
Tosot
Indoor Evaporator Temperature Sensor Fault
Indoor unit displays F2, unit may shut down or run erratically
Advertisements
Possible Causes
Open or shorted evaporator coil sensor (T1), Loose or corroded sensor connector, Sensor dislodged from coil surface, Damaged sensor harness
How to Fix / Troubleshooting
Safety first: Disconnect power before removing the front cover.
- Access the coil: Remove the front panel and filters to expose the evaporator coil.
- Locate sensor: Find the T1 sensor clipped to the coil tubing. Ensure it is firmly attached and not hanging loose.
- Check wiring: Trace the sensor wires back to the PCB and reseat the connector.
- Replace sensor: If F2 persists, replace the evaporator temperature sensor with the correct Tosot part.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Indoor Evaporator Temperature Sensor (T1)
Check Price on Amazon
We may earn a commission from links on this page.