F8
Tosot
Indoor Fan Speed Out of Control / Feedback Error
Indoor unit displays F8, unit may run at reduced capacity
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Indoor DC fan motor tachometer failure, Obstructed blower wheel, Faulty indoor PCB fan control circuit, Incorrect fan motor replacement part
How to Fix / Troubleshooting
Safety first: Disconnect power to the indoor unit.
- Inspect blower: Remove the front cover and check for dirt buildup or foreign objects in the blower wheel. Clean thoroughly.
- Check motor connector: Reseat the indoor fan motor connector on the PCB.
- Verify correct motor: If the motor was recently replaced, confirm it is the exact Tosot-specified DC motor model.
- Test operation: Restore power and run the fan at different speeds. If F8 returns, replace the indoor DC fan motor. If still unresolved, the indoor PCB may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Indoor DC Fan Motor