F9
Tosot
Indoor Coil Outlet Temperature Sensor Fault
Indoor unit shows F9, irregular temperature control or shutdowns
Advertisements
Possible Causes
Defective outlet temperature sensor on indoor coil, Sensor not properly attached, Wiring harness damage, Indoor PCB sensor circuit failure
How to Fix / Troubleshooting
Safety first: Turn off power before removing covers.
- Locate outlet sensor: This sensor is typically clipped to the outlet side of the indoor evaporator coil.
- Check attachment and wiring: Ensure it is firmly attached and the wires are intact. Reseat the connector on the PCB.
- Replace sensor: If F9 persists, replace the outlet temperature sensor with the correct Tosot part.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Indoor Coil Outlet Temperature Sensor
Check Price on Amazon