Tosot Indoor Blower Failure

Outdoor unit is running but indoor fan does not blow air

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed indoor DC fan motor, Loose fan motor connector, Obstructed blower wheel, Faulty indoor PCB fan driver

How to Fix / Troubleshooting

Safety first: Turn off power to the indoor unit.

  • Check for obstructions: Remove the front panel and inspect the blower wheel for foreign objects or heavy dust buildup. Clean thoroughly.
  • Spin test: Try spinning the blower by hand. If stiff or seized, the motor likely needs replacement.
  • Inspect wiring: Reseat the fan motor connector on the indoor PCB.
  • If fan still does not run: Replace the indoor DC fan motor. If the new motor does not run, the indoor PCB may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor DC Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements