F4
Trane
Condenser Coil Temperature Sensor Fault
Trane air conditioner displays F4 and may limit compressor operation; defrost or protection modes may be affected on heat pump models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted condenser coil sensor, Sensor dislodged from coil, Damaged sensor harness, Faulty outdoor control board input
How to Fix / Troubleshooting
Safety first: Shut off power to the outdoor unit before removing panels.
- Find coil sensor: Look for a small sensor clipped to the condenser coil tubing. Ensure it is firmly clipped and making good contact.
- Check wiring: Inspect the sensor wires for damage and verify the connector is secure on the control board.
- Clean area: Remove debris and dirt around the sensor to ensure accurate temperature readings.
If F4 remains, the condenser coil sensor should be replaced with a Trane OEM part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Trane Condenser Coil Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.