Outdoor Unit Not Responding to Cooling Call
Trane air conditioner indoor blower runs but outdoor unit does not; warm air blows from vents.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed contactor coil, Broken low-voltage wire to outdoor unit, Blown low-voltage fuse on indoor board, Faulty thermostat output
How to Fix / Troubleshooting
Safety first: Turn off power to both indoor and outdoor units before accessing wiring.
- Check low-voltage fuse: Inspect the 3–5A blade fuse on the indoor Trane control board. Replace if blown, but look for shorts in thermostat or outdoor wiring.
- Inspect thermostat cable: At the outdoor unit, verify the Y and C wires are securely connected and not corroded or broken.
- Test contactor manually: With power on and extreme caution, press the contactor plunger with an insulated tool. If the compressor and fan start, the contactor coil is not being energized or is open.
- Thermostat check: Bypass the thermostat by temporarily connecting R to Y at the indoor control board. If the outdoor unit starts, the thermostat or its wiring is suspect.
Replace the contactor or repair low-voltage wiring as needed. If unsure, have a Trane technician perform the diagnosis.