Trane Poor Cooling Performance / Underperformance

Trane air conditioner runs but does not cool well; supply air is only slightly cooler than room temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge, Dirty evaporator coil, Dirty condenser coil, Restricted airflow due to clogged filter

How to Fix / Troubleshooting

Safety first: Turn off power before cleaning coils or filters. Do not attempt to adjust refrigerant charge yourself.

  • Replace filter: Install a new air filter of the correct size and rating.
  • Clean indoor coil: If accessible, gently brush dust from the evaporator coil and use a no-rinse coil cleaner. Ensure condensate drain is clear.
  • Clean outdoor coil: Remove debris and wash the Trane condenser coil from inside out with low-pressure water.
  • Check temperature drop: With system running 15–20 minutes, measure temperature at a return grille and nearest supply vent. A typical drop is 15–20°F. Significantly less may indicate low charge or other issues requiring a technician.

If performance remains poor after cleaning and airflow corrections, schedule a Trane technician to check refrigerant charge and system capacity.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Trane Evaporator Coil
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements