Tristar
Insufficient Cooling Capacity / Performance Degradation
Air conditioner runs but does not cool the room effectively; supply air feels only slightly cooler than room air.
Advertisements
Possible Causes
Dirty indoor or outdoor coils, Clogged air filters, Low refrigerant charge, Undersized unit for room size
How to Fix / Troubleshooting
Safety first: Turn off power before cleaning coils or filters.
Steps to try:
- Clean filters: Wash or replace all air filters.
- Clean coils: Gently clean indoor and outdoor coils with a soft brush and appropriate coil cleaner.
- Check doors and windows: Close windows and minimize heat sources (ovens, direct sun without blinds).
- Measure temperature drop: After 15 minutes of operation, measure air temperature at return and supply. A typical drop is 8–12°C. If much lower, refrigerant or mechanical issues may exist.
When to call a technician: If cleaning and load reduction do not restore performance, have a technician check refrigerant charge and system pressures.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Indoor Evaporator Coil
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements