E9
Tristar Full Condensate Pan / Drainage Fault

Unit shows E9 and may shut down unexpectedly; sometimes associated with water leakage from indoor unit.

Advertisements

Possible Causes

Blocked condensate drain hose, Clogged internal drain pan outlet, Kinked or improperly sloped drain line, Failed condensate pump (on some cassette or floor models)

How to Fix / Troubleshooting

Safety first: Turn off power to avoid electrical hazards from water near electronics.

Steps to try:

  • Check drain hose: Locate the drain hose exiting the indoor unit. Ensure it slopes downward continuously and is not kinked or elevated.
  • Clear blockage: Detach the hose end and blow through it or use a wet/dry vacuum at the outlet to remove sludge and algae.
  • Clean drain pan: Remove the front cover and inspect the drain pan under the evaporator. Remove debris and flush with warm water and a mild disinfectant.
  • Inspect condensate pump (if fitted): Listen for pump operation. If silent and the pan is full, the pump may have failed and needs replacement.

When to call a technician: If E9 persists after clearing the drain, the float switch or pump assembly may be defective and should be serviced professionally.