F4
Tristar
Compressor Discharge Temperature Protection
Unit displays F4 and does not start compressor; fan may still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked outdoor coil or airflow, Low refrigerant charge causing overheating, Faulty discharge temperature sensor, Non-condensable gases in system
How to Fix / Troubleshooting
Safety first: Turn off power. Do not touch hot refrigerant lines immediately after shutdown.
User-level steps:
- Clean outdoor coil: Remove debris and wash fins gently.
- Check outdoor fan: Ensure the fan runs at full speed when the unit is on.
- Shade and ventilation: Ensure the outdoor unit is not enclosed or exposed to extreme direct heat without airflow.
Technician-required: A professional should verify discharge sensor operation, refrigerant charge, and system pressures.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Discharge Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.