F2
Vaillant Indoor Pipe / Liquid Line Temperature Sensor Fault

F2 displayed, unit stops or runs only briefly, poor temperature control

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective indoor liquid pipe NTC sensor, Sensor not properly attached to refrigerant pipe, Damaged sensor harness, Indoor PCB sensor input failure

How to Fix / Troubleshooting

Safety: Disconnect mains power before opening the indoor unit.

  • Find the pipe sensor: Remove the front cover and right‑side electrical cover. The pipe sensor is usually strapped to a copper refrigerant pipe near the expansion device or coil outlet.
  • Check attachment: Ensure the sensor is tightly strapped to the pipe with its metal tip in full contact. Re‑secure with new cable ties or thermal tape if loose.
  • Inspect cable: Look for crushed or cut insulation where the pipe sensor cable passes through metal brackets. Repair minor insulation damage with high‑quality electrical tape; replace the sensor if conductors are damaged.
  • Test sensor: Unplug from the PCB and measure resistance. Compare to Vaillant’s NTC chart. Replace if open, shorted, or clearly out of range.
  • Install replacement: Fit the new indoor pipe NTC sensor in the same location, firmly strapped to the copper pipe, and route the cable along the original path.
  • Restart: Restore power, clear the error by cycling power from the remote, and verify stable operation in both COOL and HEAT modes.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Pipe NTC Temperature Sensor
Check Price on Amazon