F9
Vaillant Indoor Return Air / Auxiliary Temperature Sensor Fault

F9 error, unit stops and may show abnormal temperature readings

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Auxiliary NTC sensor open or shorted, Sensor dislodged from return air path, Damaged sensor harness, Indoor PCB sensor channel failure

How to Fix / Troubleshooting

Safety: Switch off power at the breaker before opening the indoor unit.

  • Locate auxiliary sensor: Some Vaillant models have a second room or return air sensor near the filter or behind the front grille. Identify the small NTC sensor and its wiring.
  • Check placement: Ensure the sensor is positioned in the airflow, not touching metal parts that could skew readings.
  • Inspect wiring: Follow the cable to the PCB, checking for damage or loose connectors. Reseat the plug.
  • Measure resistance: Unplug and test with a multimeter. Compare to the expected resistance at room temperature. Replace if out of range.
  • Replace sensor: Install a new indoor auxiliary NTC sensor if needed, securing it in the correct location.
  • Test: Restore power and verify that F9 clears and that room temperature readings are stable.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Auxiliary NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements