Vaillant Thermostat / Sensor Placement or Oversizing Issue

Indoor unit frequently turns on and off, room temperature fluctuates widely

Advertisements

Possible Causes

Room sensor located too close to supply air, Sensor not properly clipped, Oversized Vaillant unit for room size, Airflow short‑circuit due to louver direction

How to Fix / Troubleshooting

Safety: Isolate power before adjusting internal sensors.

  • Check sensor location: Ensure the indoor ambient sensor is positioned to sense room air, not directly in the cold supply stream.
  • Adjust louvers: Aim the louvers horizontally or slightly upward to avoid blowing directly on the sensor area.
  • Verify sensor clip: Confirm the sensor is firmly clipped in its designated holder and not dangling.
  • Use appropriate mode: Avoid setting the temperature extremely low or high; use moderate setpoints to reduce cycling.
  • If problem persists: A Vaillant technician can evaluate sensor calibration and system sizing.