Vaillant
Indoor Fan Control or Louver Closed
Outdoor unit runs but indoor unit does not blow air (no airflow from vents)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Louver stuck in closed position, Indoor fan motor failure, Fan relay or triac failure on indoor PCB, Incorrect mode or fan setting
How to Fix / Troubleshooting
Safety: Turn off power before opening the indoor unit.
- Check mode and fan setting: Ensure the unit is not in DRY mode with very low fan speed. Set fan to HIGH and mode to COOL or HEAT.
- Inspect louvers: Confirm that the louvers open when the unit starts. If not, see the louver motor fault procedure.
- Fan motor check: If louvers open but no air is felt, inspect the fan motor and its connector. Replace the indoor fan motor if non‑functional.
- PCB output: If the motor is good but not receiving power, the indoor PCB may be faulty and should be replaced by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Indoor Fan Motor Assembly
Check Price on Amazon