F2
Viessmann
Indoor Coil Sensor Out of Range
Indoor unit shows F2; coil temperature reading appears abnormal in diagnostics
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Sensor not in good thermal contact with coil, Sensor damaged by corrosion or cleaning chemicals, Wiring harness partially broken, Indoor PCB sensor input fault
How to Fix / Troubleshooting
Safety: Isolate power before working on the coil area.
- Re-seat sensor: Ensure the sensor is tightly clipped to the coil tube or fin with good contact.
- Inspect for corrosion: Replace the sensor if the casing is cracked or corroded.
- Check harness continuity: Wiggle the cable gently while measuring resistance to detect intermittent breaks.
If F2 persists with a new sensor and good wiring, the indoor PCB likely needs replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements