Reduced Cooling Capacity / Underperformance
Air conditioner runs but does not cool the room effectively; air from vents is only slightly cool.
Advertisements
Possible Causes
Dirty indoor evaporator coil, dirty outdoor condenser coil, low refrigerant charge, undersized unit for room, indoor fan not at correct speed
How to Fix / Troubleshooting
Safety: Turn off power before cleaning coils or removing covers.
Steps:
- Check thermostat setting: Ensure the mode is set to COOL and the set temperature is at least 3–5°C below room temperature.
- Clean filter: Remove and clean the air filter thoroughly.
- Clean indoor coil: With the front panel removed, gently vacuum the evaporator fins. Use a coil cleaner approved for aluminum fins if heavily soiled.
- Clean outdoor coil: Remove debris and wash the condenser coil with low-pressure water, avoiding the control box.
- Check fan speeds: Ensure the indoor fan is set to HIGH for maximum cooling.
- Room size check: Compare the unit's BTU rating to the room size; if the room is too large, the unit may never reach setpoint.
- Professional check: If performance is still poor, have a technician check refrigerant charge and system pressures.