F1
Westinghouse Indoor Ambient Sensor Out of Range (Alternate Code Set)

Display shows F1 and unit may not respond to temperature changes correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Drifted thermistor value, sensor placed in wrong location, wiring damage, PCB analog-to-digital converter fault

How to Fix / Troubleshooting

Safety: Turn off power before removing the front panel.

Steps:

  • Check sensor placement: Ensure the indoor ambient sensor is located in the return air stream, not touching the coil or metal frame.
  • Inspect wiring: Look for kinks, pinches, or cuts in the sensor leads. Reseat the connector on the PCB.
  • Compare temperature: If the unit displays a room temperature that is clearly wrong (e.g., 10–15°C off), the sensor is likely faulty.
  • Replace sensor: Install a new Westinghouse indoor ambient thermistor and secure it in the correct location.
  • PCB check: If a new sensor does not correct the reading or clear F1, the indoor PCB may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Ambient Thermistor (Room Temperature Sensor)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements