Westinghouse Outdoor Fan Failure

Outdoor unit fan does not run, but compressor is operating; outdoor unit becomes very hot.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor fan motor, faulty fan capacitor (if used), seized fan bearings, defective outdoor PCB fan relay or triac

How to Fix / Troubleshooting

Safety: Turn off power immediately to prevent compressor damage.

Steps:

  • Inspect fan: With power off, try to spin the fan blade by hand. If stiff or seized, the motor likely needs replacement.
  • Check capacitor: On non-inverter units, inspect and test the fan capacitor; replace if bulged or out of spec.
  • Wiring: Check fan motor wiring and connectors for burns or loose connections.
  • PCB output: A technician should verify that the PCB is sending voltage to the fan motor when commanded.

Do not run the unit until the fan issue is corrected; overheating can destroy the compressor.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.