F3
Whirlpool Outdoor Coil Sensor / Defrost Sensor Fault

Whirlpool air conditioner displays F3 and may not defrost or may shut down in heating mode (for heat pump models).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted outdoor coil thermistor, sensor not attached to coil, damaged wiring, failed outdoor PCB

How to Fix / Troubleshooting

Safety: Turn off power at the breaker. Outdoor units contain high-voltage components.

Steps:

  • Remove the outdoor unit service panel.
  • Locate the outdoor coil sensor clipped to the condenser/heat pump coil.
  • Inspect for physical damage and secure attachment to the coil.
  • Test resistance with a multimeter and compare to Whirlpool specifications.
  • Replace the outdoor coil sensor if readings are out of range.

If F3 persists with a good sensor, the outdoor control board may be defective and should be replaced by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Coil Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements