F1
Whynter
Indoor Ambient Sensor Calibration / Range Error
Display shows F1 and unit may not respond to temperature adjustments.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Ambient thermistor out of calibration, Sensor reading out of expected range, Loose sensor connection, Main PCB firmware issue
How to Fix / Troubleshooting
Safety: Unplug the unit before opening.
- Power reset: Disconnect power for 10 minutes and reconnect to clear transient faults.
- Check ambient sensor: Access the control area and locate the room temperature sensor near the air intake. Ensure it is not touching hot components or the evaporator coil.
- Reposition sensor: If the sensor is too close to the coil or enclosed in insulation, reposition it so it measures true room air.
- Connector check: Reseat the sensor connector on the main PCB.
- Replace sensor: If F1 persists and the sensor resistance is out of spec, replace the ambient temperature sensor.
- Board/firmware: Persistent F1 after sensor replacement may indicate a main PCB firmware issue; replace the main control PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient Temperature Sensor
Check Price on Amazon