F2
Whynter Evaporator Sensor Calibration / Range Error

Display shows F2 and unit may shut down or not cool properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator thermistor out of range, Sensor not making good contact with coil, Loose connector, Main PCB fault

How to Fix / Troubleshooting

Safety: Unplug the unit.

  • Access evaporator: Remove front or side panels to expose the evaporator coil.
  • Verify sensor placement: Ensure the evaporator sensor is firmly attached to the coil tubing or fins with good thermal contact.
  • Inspect wiring: Check for damage or loose connections between the sensor and main PCB.
  • Test resistance: Compare sensor resistance to the ambient sensor at similar temperature. Replace the evaporator temperature sensor if readings are abnormal.
  • Control board: If F2 remains after sensor replacement, the main control PCB may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.