H8
Whynter System Overload / Current Protection Fault

Display shows H8 and unit stops heating or cooling; may indicate overload protection.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted compressor or fan motor, Blocked airflow causing high current draw, Faulty power relay on main PCB, Incorrect supply voltage

How to Fix / Troubleshooting

Safety: Unplug the unit. Do not repeatedly reset breakers without finding the cause.

  • Check supply: Verify the unit is on the correct voltage circuit and not sharing a circuit with heavy loads.
  • Inspect airflow: Clean filters and coils, and ensure exhaust hose (portable) is clear.
  • Visual inspection: Open the electrical compartment and look for burnt wires, melted connectors, or charred components on the main PCB.
  • Motor/compressor test (advanced): With power disconnected, measure resistance of compressor and fan windings. Very low resistance or continuity to ground indicates a shorted component that must be replaced.
  • Replace failed component: Replace the compressor, fan motor, or main control PCB as indicated by testing. This level of repair is best handled by a professional.