E3
York
Discharge Temperature High / Compressor Overheat
York air conditioner displays E3 and shuts down shortly after starting
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser coil, Failing condenser fan motor, Overcharged refrigerant, Non‑condensables or restricted liquid line filter‑drier
How to Fix / Troubleshooting
Safety: Disconnect power at the outdoor disconnect and indoor breaker. Components around the compressor can be very hot.
- Clean the condenser coil: Remove the top grille of the York condensing unit (support the fan assembly) and clean the coil from inside out with low‑pressure water. Avoid bending fins.
- Check condenser fan: Spin the fan blade by hand (power off). If stiff or noisy, the motor bearings may be failing. Test the fan capacitor with a meter and replace if out of tolerance.
- Inspect for airflow obstructions: Ensure at least 2–3 feet of clearance around the unit and no hot exhaust blowing onto it.
- Filter‑drier and liquid line: If the liquid line filter‑drier is cold with a big temperature drop across it or visibly frosted, it may be restricted and should be replaced by a technician.
- Refrigerant issues: Overcharge or non‑condensables require a licensed tech to recover, evacuate, and recharge per York nameplate data.
Advertisements
Repair Difficulty
Hard
4/5