E9
York Full Drain Pan / Drainage Fault

York ductless AC shows E9 and stops cooling, often with water dripping from the indoor unit

Advertisements

Possible Causes

Clogged condensate drain line, Blocked drain pan outlet, Improper indoor unit leveling, Failed condensate pump (if equipped)

How to Fix / Troubleshooting

Safety: Turn off power to the indoor unit. Water may spill when opening panels.

  • Inspect and clean drain line: Locate the PVC or vinyl drain line from the York indoor unit. Use a wet/dry vacuum at the outside termination to suck out sludge and algae. Flush with warm water and a small amount of mild bleach if local codes allow.
  • Check drain pan: Remove the front cover and filters. Inspect the drain pan for standing water, algae, or debris. Clean thoroughly and ensure the outlet is clear.
  • Verify unit is level: Use a level to confirm the indoor unit is slightly pitched toward the drain outlet. Adjust mounting if necessary.
  • Condensate pump (if used): Check that the pump reservoir is clean and the float switch moves freely. If the pump does not run when the reservoir fills, replace the condensate pump.
  • Reset error: After clearing the blockage and drying the pan, restore power and test cooling operation.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Drain Line
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements