F1
York Indoor Blower Motor Fault

York air handler or furnace control board flashes F1 and blower runs erratically

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ECM blower motor, Loose blower harness, Faulty blower control on furnace/air handler board, Seized blower wheel

How to Fix / Troubleshooting

Safety: Turn off power to the furnace or air handler at the breaker and service switch.

  • Inspect blower compartment: Remove the blower access panel. Check for debris or insulation interfering with the blower wheel.
  • Check wiring harness: Reseat the multi‑pin connector between the ECM blower motor and the York control board. Look for burned pins.
  • Spin blower wheel: Rotate the wheel by hand. If it binds or scrapes, remove and clean or replace the wheel and check for housing damage.
  • Test motor: If you have the proper test module or harness, follow York procedures to test the ECM motor. If it fails to run, replace the blower motor assembly.
  • If motor is good: The furnace/air handler control board may be defective and should be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

ECM Blower Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements