H1
York Defrost Sensor or Defrost Cycle Fault

York heat pump in heating mode shows H1 and stops heating

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed defrost sensor on outdoor coil, Defrost control board malfunction, Sensor not sensing coil correctly due to poor contact, Wiring issues

How to Fix / Troubleshooting

Safety: Turn off power to the outdoor unit before servicing.

  • Check for heavy frost: Inspect the York heat pump outdoor coil. If heavily iced, airflow or defrost control is suspect.
  • Inspect defrost sensor: Locate the defrost thermistor on the coil. Ensure it is tightly attached and not corroded.
  • Test sensor: Measure resistance at known temperatures and compare to York data. Replace if readings are incorrect.
  • Check defrost board: Inspect the defrost control board for burned components or water damage. Verify correct wiring and dip switch settings.
  • If unsure: Have a technician test the defrost cycle and replace the defrost board if necessary.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost Sensor
Check Price on Amazon