AEG air fryer beeps and shows E6; touch controls may be unresponsive or erratic.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Disconnect from mains before removing the control panel or top cover.
Steps to address E6:
- Power cycle: Unplug the unit for 10 minutes to allow capacitors to discharge. Plug back in and test. If E6 returns, proceed.
- Access control panel: Remove the top/front bezel screws and gently lift off the control panel assembly. Be careful not to tear the ribbon cable.
- Check ribbon cable: Reseat the flat ribbon cable connectors at both the touch panel and main PCB ends. Ensure the locking tabs are fully engaged.
- Inspect for moisture/grease: Wipe any condensation, oil, or food residue from the back of the touch panel and around connectors with a dry, lint-free cloth. Do not use excessive liquid cleaners.
- Examine for cracks: If the touch glass or PCB is cracked, the touch control panel assembly must be replaced with an AEG-compatible part.
- Reassemble and test: Refit the panel, ensuring no cables are pinched. Power on and verify that the error is cleared and buttons respond correctly.
Note: If reseating and cleaning do not resolve E6, the fault may lie in the main control board firmware or communication circuitry, requiring board replacement.
Repair Difficulty
Required Part