Beko Drawer Latch / Switch Actuator Misalignment

Drawer will not close fully; the last few millimetres remain open and the unit will not start.

Advertisements

Possible Causes

Obstruction at back of drawer cavity, Bent drawer front or latch, Misaligned basket detection microswitch, Broken plastic actuator tab

How to Fix / Troubleshooting

Steps to fix drawer closure:

  • Check for obstructions: Remove the drawer and inspect the cavity for fallen food, screws, or warped plastic blocking closure.
  • Inspect latch area: Examine the front of the drawer and the mating area on the body for damage or deformation.
  • Check actuator tab: Ensure the plastic tab that presses the basket detection switch is intact. If broken, replace the drawer assembly or fabricate a safe repair only if it does not bypass safety.
  • Adjust switch position: Slightly loosen the screws holding the microswitch and adjust its position so the drawer can fully close while still actuating the switch.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Basket Detection Microswitch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements