E10
Beko Internal Overcurrent / Short Circuit Protection

Air fryer displays E10 and will not start; may occur after a short circuit or tripped breaker event.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted heating element to chassis, Pinched or bare wiring touching metal frame, Shorted component on main control PCB, Damaged power filter board

How to Fix / Troubleshooting

Safety first: Unplug the appliance immediately if a breaker trips or you smell burning. Do not repeatedly reset breakers without finding the cause.

Steps to address E10:

  • Visual inspection: Remove the outer housing and inspect all wiring, especially around the heater, fan motor, and where wires pass through metal panels. Look for melted insulation or blackened areas.
  • Check heater for shorts: With a multimeter, measure resistance between each heater terminal and the metal chassis. Any reading other than OL (open) indicates a shorted heater that must be replaced.
  • Inspect PCB: Examine the main control PCB and any power filter board for burnt components, cracked tracks, or soot. A visibly damaged board should be replaced.
  • Check cord entry: Ensure the power cord grommet is intact and that wires are not cut or pinched where they enter the housing.
  • Replace faulty parts: Replace any shorted heating element, damaged wiring harness, or burnt main control PCB. Use high-temperature wire where appropriate.
  • Test carefully: After repairs, reassemble fully before plugging in. Monitor for any unusual sounds or smells during the first test cycle.

Warning: If you are not experienced with electrical safety and insulation testing, seek professional service for overcurrent faults.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heating Element
Check Price on Amazon

We may earn a commission from links on this page.