E8
Black+Decker Door/basket detection switch fault

E8 is displayed and the unit will not start or shuts off immediately.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misaligned basket not engaging switch,Broken or stuck door/basket microswitch,Loose switch wiring harness,Deformed basket rail or latch

How to Fix / Troubleshooting

Safety first: Unplug the air fryer before inspecting internal switches. Avoid bypassing safety switches.

Steps to resolve door/basket detection errors:

  • 1. Check basket insertion: Remove the basket and drawer, then reinsert firmly until you hear or feel a click. Ensure no foil or food debris is preventing full closure.
  • 2. Inspect latch and rails: Examine the basket handle, latch, and side rails for warping, cracks, or buildup. Clean rails and latch points with a damp cloth.
  • 3. Locate the microswitch: With the unit unplugged, remove the side or bottom cover to access the basket/door microswitch near the front of the chassis where the basket slides in.
  • 4. Test switch operation: Manually press the switch lever; you should hear a distinct click. If it feels mushy or sticks, replace the switch.
  • 5. Electrical test: Disconnect the switch and test continuity with a multimeter while pressing and releasing the lever. If continuity does not change, the switch is faulty.
  • 6. Check wiring: Ensure the switch wires are firmly connected to the main control PCB and not pinched by the cabinet.

Never tape or jumper the switch closed; this defeats a critical safety feature.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Basket/Door Microswitch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements