E08
Bosch
Control Panel / Touch Interface Error
E08 displayed; unit may not respond to temperature or time adjustments correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty capacitive touch panel, Moisture ingress behind control fascia, Loose ribbon cable between UI and main board, Failed UI controller IC
How to Fix / Troubleshooting
Safety first: Unplug the air fryer before removing the control panel.
Basic actions:
- 1. Dry the panel: If the panel was recently cleaned or exposed to steam, wipe it dry and leave the unit unplugged for several hours to allow moisture to evaporate.
- 2. Power cycle: After drying, reconnect power and test. If E08 persists, proceed to internal checks.
Internal checks (advanced):
- 3. Access control panel: Remove screws securing the front fascia or top cover to expose the touch control PCB and ribbon cable.
- 4. Inspect ribbon cable: Ensure the flat cable between the UI board and main control board is fully seated and not damaged. Reseat both ends.
- 5. Check for corrosion: Look for signs of moisture damage or corrosion on the UI PCB. Clean light corrosion with isopropyl alcohol and a soft brush.
- 6. Replace UI board: If individual buttons or touch zones remain unresponsive and E08 continues, replace the entire control panel / UI PCB assembly.
Note: Avoid spraying cleaners directly onto the control panel in the future; apply to a cloth first.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Touch Control Panel PCB
Check Price on Amazon