E10
Bosch Temperature Calibration / Sensor Range Error

E10 error; unit may not recognize temperature settings or shows unrealistic temperature values.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect NTC sensor value for model, Sensor wiring extended or modified, Control board firmware mismatch, Sensor partially shorted due to moisture

How to Fix / Troubleshooting

Safety first: Disconnect from mains and allow to cool.

Steps:

  • 1. Check for recent repairs: If the temperature sensor or control board was recently replaced, verify that the correct Bosch part numbers were used. Using a non‑matching NTC can cause E10.
  • 2. Inspect sensor harness: Ensure the sensor wires are not pinched, spliced, or extended. Any modification can change resistance and calibration.
  • 3. Dry the sensor: If the unit was washed aggressively or exposed to steam, moisture may have entered the sensor well. Allow the unit to dry for 24 hours in a warm, dry environment.
  • 4. Replace sensor: If E10 persists and the sensor reading is unstable, replace the NTC sensor with the exact Bosch‑specified component.
  • 5. Firmware / board: In rare cases, a mismatched or corrupted control board firmware can cause calibration errors. Replacement of the control board may be required via Bosch service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements