E9
Breville Low Voltage / Power Supply Fault

E9 appears and the unit may not power up fully or may shut off randomly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed internal power supply on main control board, Loose AC input connections, Damaged power cord, Faulty line filter board (if equipped)

How to Fix / Troubleshooting

Safety first: Unplug the unit. Power supply troubleshooting involves exposure to mains voltage; proceed only if you are trained and equipped.

  • Check outlet: Verify the wall outlet is delivering correct voltage using another appliance or a tester. Avoid using extension cords or power strips.
  • Inspect power cord: Examine the power cord for cuts, kinks, or burn marks. Replace if any damage is found.
  • Check internal connections: Remove the cover and inspect the AC input terminals, strain relief, and any line filter board for loose screws or connectors.
  • Visual board inspection: On the main control board, look for bulged capacitors, burned resistors, or cracked solder joints in the power supply section.
  • Board replacement: If there are clear signs of power supply failure, replace the main control board as a complete assembly. Component-level repair is not recommended for most users.

If you are not experienced with mains electronics, have a professional perform these checks.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon